Installing a Built-In Induction Hob in Malaysia

Most failed drop-in jobs are joinery, not electronics. Cut to the written dimensions, leave the cupboard breathing, and hard-wire the circuit before you power the glass.

Written by Better IH Malaysia · Updated 25 August 2026 · For Malaysian homes and commercial kitchens

Install sequence (do not reverse it)

  • Lock the model from built-in induction hobs and copy L × W × H, cut-out, and wattage from the product page.
  • Give those millimetres to the carpenter. Do not copy a hole from another brand.
  • Give wattage and voltage to the electrician for a dedicated circuit and isolator — electrical requirements.
  • Order the hob after the cut-out and cable route exist, not the other way around.

If the counter cannot be cut, stop. You want a tabletop induction cooker, not a homemade hole around a tabletop body. See built-in vs tabletop.

Cut-out: millimetres, not “about the same as the last hob”

Stone and stainless are unforgiving. A hole 8 mm too small will not take the glass; a hole too large leaves the hob sitting on clips with a grease trap around the edge. Use the cut-out figure on that model’s page (for example BT-350T or AP-F35 if the control panel is separate). Wok built-ins often need a different opening than a flat two-zone hob.

The cupboard has to breathe

A built-in induction hob dumps heat into the cabinet. Close that space with no inlet or outlet and the electronics will throttle or cut out on a correctly sized circuit. Leave the clearance the datasheet asks for, keep the fan path open, and do not store cookware jammed against the underside. Malaysian kitchens that “seal the cupboard for cockroaches” without a vent path are a common callback.

Cable, isolator, and commissioning

Plan cable entry through the cabinet so the glass can lift for service. Put an isolator where the cook or technician can reach it. A 3.5 kW hob is not a 13 A trailing socket. After first power-up, confirm pan detection with a known magnetic pan — cookware / magnet test — before you blame the electronics.

Apartments and hotel counters

Management corporations and hotel engineers often care about fire, noise, and shared boards more than the glass colour. The apartment guide covers MC rules. Hotel breakfast lines still need the same cut-out and ventilation rules; guests seeing flush glass does not waive under-counter airflow.

Frequently asked questions

Can the carpenter copy a cut-out from my old hob?

Only if the millimetres match this model’s product page. Brands are not interchangeable. Measure twice, cut once, from the written drawing.

Why did the hob cut out after we closed the cupboard?

Usually heat build-up under the counter, not a failed coil. Restore the ventilation gap and keep the fan intake clear.

Who should connect the cable?

A competent electrician, especially for hard-wired commercial bodies. Better IH Malaysia can confirm wattage and voltage; we do not replace the licensed installer.

Related equipment

These category pages list models with written wattage, voltage, and dimensions.

Related guides